{"id":853,"date":"2024-12-19T13:31:43","date_gmt":"2024-12-19T13:31:43","guid":{"rendered":"http:\/\/www.perimed-instruments.com\/us\/?post_type=application&#038;p=853"},"modified":"2025-01-15T13:27:22","modified_gmt":"2025-01-15T13:27:22","slug":"cam-assay","status":"publish","type":"application","link":"https:\/\/www.perimed-instruments.com\/us\/applications\/preclinical-research\/cam-assay\/","title":{"rendered":"CAM assay"},"content":{"rendered":"<section class=\"relative w-full mx-auto pt-24 2xl:pt-24 pb-24 2xl:pb-24 none\">\n                                                \n                                        <div class=\"sec-bg sec-bg-laptop absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/bg-hero-white-blur-right.webp);background-size:cover;background-position:center;\"><\/div>\n                                        <div class=\"sec-bg sec-bg-mobile absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/bg-hero-white-blur-right.webp);background-size:cover;background-position:center;\"><\/div>\n                                        <div class=\"sec-bg sec-bg-wide absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/bg-hero-white-blur-right.webp);background-size:cover;background-position:center;\"><\/div>\n                                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group is-content-justification-left is-layout-constrained wp-container-core-group-is-layout-4d085cea wp-block-group-is-layout-constrained\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/www.perimed-instruments.com\/us\/\">Home<\/a><\/span> \/ <span><a href=\"https:\/\/www.perimed-instruments.com\/us\/applications\/\">Applications<\/a><\/span> \/ <span><a href=\"https:\/\/www.perimed-instruments.com\/us\/applications\/preclinical-research\/\">Preclinical research<\/a><\/span> \/ <span class=\"breadcrumb_last\" aria-current=\"page\">CAM assay<\/span><\/span><\/div>\n\n\n<h1 class=\"wp-block-heading pb-8 has-h-1-font-size\">Chorioallantoic membrane \u2014 CAM assay<\/h1>\n\n\n\n<p class=\"has-text-hero-font-size\" style=\"font-style:normal;font-weight:400\">The CAM assay is a versatile animal model for studying tumor formation, angiogenesis, and metastasis. It is highly reproducible, cost-effective, and has a natural immunodeficiency making it suitable for cell transplantation. The model relies on the creation of a window in the shell of a fertilized chicken egg, which enables researchers to observe the embryo and the formation of blood vessels.<\/p>\n\n\n<div class=\"gn-spacer-block pb-10\">\n    <\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"#learn-more\">Learn more<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\"><div class=\"block-img relative   \" >\n                                        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/picture-cam-assay.webp\" alt=\"\"\n                    width=\"800\" height=\"550\" class=\" has-round-corners\">\n                                <\/div>\n            <\/div>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-24 2xl:pt-24 pb-12 2xl:pb-12 none\" id=\"learn-more\">\n                        \n\n        <div class=\"section__content  max-w-4xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<h2 class=\"wp-block-heading has-h-2-font-size\">Measuring with PeriCAM PSI HR<\/h2>\n\n\n<div class=\"block-img relative   \" >\n                                            <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/2024\/11\/Shadow_Circle_Illustration_Down_Left_85_.webp\" alt=\"Background image\" class=\"img_bg\"\n                    style=\"top:-30px; left:-110px; bottom:0; right:-0px;\" width=\"800\" height=\"634\">\n                                        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/pericam-psi-hr.webp\" alt=\"\"\n                    width=\"800\" height=\"634\" class=\" has-round-corners\">\n                                <\/div>\n            \n\n<div class=\"gn-spacer-block pb-12\">\n    <\/div>\n\n\n\n<p class=\"has-p-regular-font-size\">PeriCam PSI can be used to measure the (change in) blood perfusion in the angiogenesis assay and detect differences in the efficacy of various pro-angiogenic compounds.<\/p>\n\n\n\n<p class=\"has-p-regular-font-size\">The data enables you to monitor the formation of functional intratumoral blood vessels<sup><a href=\"#references\">[1]<\/a><\/sup> and validate the effectiveness of anti-angiogenic agents for cancer treatment.<\/p>\n\n\n<div class=\"gn-spacer-block pb-4\">\n    <\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-12 2xl:pt-12 pb-12 2xl:pb-12 none\">\n                        \n\n        <div class=\"section__content  max-w-4xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<h3 class=\"wp-block-heading has-h-2-font-size\">Overcoming data challenges<\/h3>\n\n\n\n<p class=\"has-p-regular-font-size\">Researchers often use the CAM assay to study angiogenesis, which requires detailed measurements of blood vessel growth, density, and branching patterns. Quantifying these changes using image-based methods can be challenging as varying light conditions and magnification can make it difficult to standardize measurements and achieve reproducible data. PeriCam PSI HR includes automated background compensation and features for setting measurement distance and magnification.<\/p>\n\n\n\n<p class=\"has-p-regular-font-size\">High-resolution imaging is required to capture subtle vascular changes on the CAM. Achieving consistently high image quality without introducing artifacts can be difficult. The translucent nature of the CAM and its sensitivity to light exposure can impact image clarity. PeriCam PSI HR records at a frequency of up to 100 images per second with a max resolution of 10 \u03bcm\/pixel. Leveraging LSCI. PeriCam PSI HR enables researchers to capture dynamic changes in microcirculation and tissue perfusion with precision.<\/p>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-12 2xl:pt-12 pb-12 2xl:pb-12 none\">\n                        \n\n        <div class=\"section__content  max-w-4xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<h3 class=\"wp-block-heading\">PeriCam PSI HR<\/h3>\n\n\n\n<p class=\"has-p-regular-font-size\">PeriCam PSI leverages laser speckle contrast imaging (LSCI) to assess blood perfusion in tissue at the microcirculation level with detail and precision. PeriCam PSI HR (high resolution) works from a fixed distance and is specifically equipped to measure small animals such as rats and mice.<\/p>\n\n\n<div class=\"gn-spacer-block pb-4\">\n    <\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li class=\"has-p-regular-font-size\">Rapid data analysis, delivering perfusion graphs, images, and video recordings in real-time.<\/li>\n\n\n\n<li>Regions of interest (ROIs) and time periods of interest (TOIs) that can be defined and updated before, during, and after recording.<\/li>\n\n\n\n<li>Frequency of up to ~100 images per second.<\/li>\n\n\n\n<li>Automated background compensation for robust measurements under varying lighting conditions.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"wp-block-list\">\n<li>Suitable for longitudinal studies.<\/li>\n\n\n\n<li>High-quality arm with good maneuverability to ease positioning, and stability to prevent movement artifacts.&nbsp;<\/li>\n\n\n\n<li>Wide-angled color camera for documentation of the measurement area and its surroundings, easing post-measurement analysis.<\/li>\n\n\n\n<li class=\"has-p-regular-font-size\">Non-contact, non-destructive, and noninvasive.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full side-margins radius-8 mx-auto pt-24 pb-24 none\">\n                    <div class=\"sec-bg-color absolute top-0 inset-0 flex justify-center overflow-hidden w-full h-full pointer-events-none z-[-2]\"  style=\"background-color:#ddebff;\">\n            <\/div>\n                                                \n                                        <div class=\"sec-bg sec-bg-laptop absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/2024\/11\/bg-application.jpg);background-size:cover;background-position:center;\"><\/div>\n                                        <div class=\"sec-bg sec-bg-mobile absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/2024\/11\/bg-application.jpg);background-size:cover;background-position:center;\"><\/div>\n                                        <div class=\"sec-bg sec-bg-wide absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/bg-products-03.webp);background-size:cover;background-position:center;\"><\/div>\n                                        \n\n        <div class=\"section__content  max-w-4xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<h2 class=\"wp-block-heading has-h-2-font-size\">Related products<\/h2>\n\n\n<div class=\"gn-spacer-block pb-4\">\n    <\/div>\n\n\n<div class=\"products-grid grid grid-cols-1 md:grid-cols-2 gap-8 \"\n        >\n                    \n            <div class=\"product-card bg-white rounded-[7px] overflow-hidden\">\n                                    <a href=\"https:\/\/www.perimed-instruments.com\/us\/products\/pericam-imaging-systems\/pericam-psi\/nr\/\">\n                                                    <div class=\"aspect-w-16 aspect-h-9\">\n                        <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/pericam-psi-nr-bg-2.webp\" alt=\"PeriCam PSI NR\" class=\"object-cover w-full h-full\">\n                    <\/div>\n                \n                <div class=\"p-6\">\n                    <div style=\"display: none;\">product-type <\/div>\n                    \n                    <h3 class=\"pb-2\">\n                        PeriCam PSI NR\n                    <\/h3>\n\n                                            <div class=\"text-black mb-8 text-lg product-excerpt\">\n                            PeriCam PSI NR is a high-resolution, laser-based, noninvasive instrument that leverages laser speckle contrast imaging (LSCI) to deliver blood perfusion measurements with precision in real-time.\n                        <\/div>\n                    \n                                            <div>\n                            <span class=\"inline-flex items-center text-black product-read-more-link\">\n                                <span class=\"mr-6 font-medium\">\n                                    Show product\n                                <\/span>\n                                <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/themes\/perimed\/public\/images\/arrow-right.d1b3f7.svg\" alt=\"Arrow right\" class=\"mt-1 w-4 h-4\">\n                                <span class=\"sr-only\">about PeriCam PSI NR<\/span>\n                            <\/span>\n                        <\/div>\n                                    <\/div>\n                                    <\/a>\n                            <\/div>\n                    \n            <div class=\"product-card bg-white rounded-[7px] overflow-hidden\">\n                                    <a href=\"https:\/\/www.perimed-instruments.com\/us\/products\/pericam-imaging-systems\/pericam-psi\/hr\/\">\n                                                    <div class=\"aspect-w-16 aspect-h-9\">\n                        <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/pericam-psi-hr-bg-2.webp\" alt=\"PeriCam PSI HR\" class=\"object-cover w-full h-full\">\n                    <\/div>\n                \n                <div class=\"p-6\">\n                    <div style=\"display: none;\">product-type <\/div>\n                    \n                    <h3 class=\"pb-2\">\n                        PeriCam PSI HR\n                    <\/h3>\n\n                                            <div class=\"text-black mb-8 text-lg product-excerpt\">\n                            Primarily designed for preclinical research, PeriCam PSI HR leverages laser speckle contrast imaging (LSCI) to measure blood perfusion in tissue at the microcirculation level with precision in real-time.\n                        <\/div>\n                    \n                                            <div>\n                            <span class=\"inline-flex items-center text-black product-read-more-link\">\n                                <span class=\"mr-6 font-medium\">\n                                    Show product\n                                <\/span>\n                                <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/themes\/perimed\/public\/images\/arrow-right.d1b3f7.svg\" alt=\"Arrow right\" class=\"mt-1 w-4 h-4\">\n                                <span class=\"sr-only\">about PeriCam PSI HR<\/span>\n                            <\/span>\n                        <\/div>\n                                    <\/div>\n                                    <\/a>\n                            <\/div>\n            <\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<div class=\"gn-spacer-block pb-7\">\n    <\/div>\n\n\n<section class=\"relative w-full side-margins radius-8 form-bg mx-auto pt-20 2xl:pt-20 pb-20 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-white-color has-text-color has-link-color has-subheader-font-size wp-elements-d460a9b4f2d432b35f4358244135c513\">Contact us<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-white-color has-text-color has-link-color wp-elements-113566be2ea58822761616eec1bf6ace\">Get in touch<\/h2>\n\n\n\n<div class=\"wp-block-group is-content-justification-left is-layout-constrained wp-container-core-group-is-layout-d379e479 wp-block-group-is-layout-constrained\">\n<p class=\"has-white-color has-text-color has-link-color has-p-big-font-size wp-elements-97b31f5d7bc1f1e0911f3f1d6c898771\">For more information about using PeriCam PSI for a CAM assay or any other preclinical research application, fill out the form, and we will be in touch with you shortly.<\/p>\n<\/div>\n\n\n<div class=\"gn-spacer-block pb-10\">\n    <\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.perimed-instruments.com\/us\/contact\/distributors\/\">Or locate your nearest distributor<\/a><\/div>\n<\/div>\n\n\n<div class=\"gn-spacer-block pb-10\">\n    <\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"forms-block \" >\n            <div class=\"hs-form-frame\" data-region=\"na1\" data-form-id=\"e8e7b983-6449-44dc-a412-93c18c060218\" data-portal-id=\"19961763\"><\/div>\n    <\/div>\n<\/div>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full references mx-auto pt-12 2xl:pt-12 pb-12 2xl:pb-4 none\" id=\"references\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<p class=\"has-p-big-font-size\"><strong>References<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li class=\"has-p-tiny-font-size\">Laser speckle contrast analysis (LASCA) technology for the semiquantitative measurement of angiogenesis in in-ovo-tumor-model. Eric Pion, Claudia Asam, Anna-Lena Feder, Oliver Felthaus, Paul I. Heidekrueger,Lukas Prantl, Silke Haerteis, Thiha Aung. 2020, Microvascular Research, Vol. 133, p. 104072.<\/li>\n<\/ol>\n\n\n\n<p class=\"has-p-big-font-size\"><strong><strong>LASCA and LSCI<\/strong><\/strong><\/p>\n\n\n\n<p class=\"has-p-tiny-font-size\">Laser speckle contrast imaging (LSCI) is the innovative technology behind PeriCam PSI, offering non-contact, high-resolution perfusion imaging. The technique was first described by <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/23014683\/\">J.D. Briers and S. Webster in 1996<\/a> and referred to as laser speckle contrast analysis (LASCA). In later years, the term LSCI gained in popularity and is nowadays the more common term. However, LSCI and LASCA both refer to the same technique, providing precise and reliable perfusion data without the need for contrast agents.<\/p>\n\n\n        <\/div>\n    <\/section>\n","protected":false},"excerpt":{"rendered":"<p>The CAM assay is a versatile animal model for studying tumor formation, angiogenesis, and metastasis.<\/p>\n","protected":false},"featured_media":2155,"parent":866,"menu_order":0,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"_FSMCFIC_featured_image_caption":"","_FSMCFIC_featured_image_nocaption":"","_FSMCFIC_featured_image_hide":""},"application_cat":[27],"class_list":["post-853","application","type-application","status-publish","has-post-thumbnail","hentry","application_cat-preclinical-research"],"acf":{"page_layout":"fullwidth","page_header_style":"dark","page_hero_overlap_header":"no","page_custom_css":""},"_links":{"self":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/application\/853","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/application"}],"about":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/types\/application"}],"up":[{"embeddable":true,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/application\/866"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/media\/2155"}],"wp:attachment":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/media?parent=853"}],"wp:term":[{"taxonomy":"application_cat","embeddable":true,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/application_cat?post=853"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}