{"id":917,"date":"2024-12-20T10:53:27","date_gmt":"2024-12-20T10:53:27","guid":{"rendered":"http:\/\/www.perimed-instruments.com\/us\/?post_type=application&#038;p=917"},"modified":"2025-01-15T12:45:01","modified_gmt":"2025-01-15T12:45:01","slug":"toe-pressure-and-tbi","status":"publish","type":"application","link":"https:\/\/www.perimed-instruments.com\/us\/applications\/clinical-exams\/toe-pressure-and-tbi\/","title":{"rendered":"Toe pressure and TBI"},"content":{"rendered":"<section class=\"relative w-full mx-auto pt-24 2xl:pt-24 pb-24 2xl:pb-24 none\">\n                                                \n                                        <div class=\"sec-bg sec-bg-laptop absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/bg-hero-white-blur-right.webp);background-size:cover;background-position:center;\"><\/div>\n                                        <div class=\"sec-bg sec-bg-mobile absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/bg-hero-white-blur-right.webp);background-size:cover;background-position:center;\"><\/div>\n                                        <div class=\"sec-bg sec-bg-wide absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/bg-hero-white-blur-right.webp);background-size:cover;background-position:center;\"><\/div>\n                                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group is-content-justification-left is-layout-constrained wp-container-core-group-is-layout-4d085cea wp-block-group-is-layout-constrained\"><div class=\"yoast-breadcrumbs\"><span><span><a href=\"https:\/\/www.perimed-instruments.com\/us\/\">Home<\/a><\/span> \/ <span><a href=\"https:\/\/www.perimed-instruments.com\/us\/applications\/\">Applications<\/a><\/span> \/ <span><a href=\"https:\/\/www.perimed-instruments.com\/us\/applications\/clinical-exams\/\">Clinical exams<\/a><\/span> \/ <span class=\"breadcrumb_last\" aria-current=\"page\">Toe pressure and TBI<\/span><\/span><\/div>\n\n\n<h1 class=\"wp-block-heading pb-8 has-h-1-font-size\">Toe pressure and TBI<\/h1>\n\n\n\n<p class=\"has-text-hero-font-size\" style=\"font-style:normal;font-weight:400\">Toe pressure and TBI are noninvasive macrocirculation measurements for evaluating blood perfusion in the toes, providing critical insight into vascular health. Toe pressure measurements are useful in wound healing, detecting and managing peripheral artery disease (PAD) and chronic limb-threatening ischemia (CLTI) \u2014 especially when ankle pressure may be unreliable due to noncompressible arteries.<\/p>\n\n\n<div class=\"gn-spacer-block pb-10\">\n    <\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"#contact-form\">Contact Sales<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image alignright size-full is-style-rounded\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"550\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/toe-pressure.webp\" alt=\"toe pressure\" class=\"wp-image-1709\" srcset=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/toe-pressure.webp 800w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/toe-pressure-300x206.webp 300w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/toe-pressure-768x528.webp 768w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/toe-pressure-769x530.webp 769w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-24 2xl:pt-24 pb-12 2xl:pb-12 none\" id=\"learn-more\">\n                        \n\n        <div class=\"section__content  max-w-4xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<h2 class=\"wp-block-heading\">Toe pressure versus TBI<\/h2>\n\n\n\n<p class=\"has-text-20-font-size\">Toe pressure is the absolute measurement of local blood perfusion in the toes and its thresholds are used in a variety of clinical assessments. TBI is the ratio of toe pressure to brachial (arm) pressure.&nbsp;By accounting for variations in systemic blood pressure, TBI normalizes toe pressure which helps clinicians interpret low toe perfusion values.&nbsp;<\/p>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto  pb-12 2xl:pb-12 none\">\n                        \n\n        <div class=\"section__content  max-w-4xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<h3 class=\"wp-block-heading\">Clinical significance of toe pressure<\/h3>\n\n\n\n<p class=\"has-p-regular-font-size\">The small arteries in the toes are less likely to be calcified than larger vessels like those in the ankle <sup><a href=\"#references\">[1]<\/a><\/sup>. This makes toe pressure and TBI measurements useful when diagnosing patients with diabetes or chronic kidney disease \u2014 where arterial calcification can render ankle-brachial index (ABI) measurements inaccurate.<\/p>\n\n\n\n<p>Toe pressure provides insights into:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Peripheral blood perfusion \u2014 helps evaluate the severity of arterial disease.<\/li>\n\n\n\n<li>Wound healing potential \u2014 indicates whether blood perfusion is sufficient to support tissue repair.<\/li>\n\n\n\n<li>Revascularization outcomes \u2014 assess change in circulation after surgical or endovascular interventions.<\/li>\n<\/ul>\n\n\n\n<p class=\"has-p-regular-font-size\">Low toe pressures (&lt;30 mmHg) are strongly associated with critical ischemia <sup><a href=\"#references\">[2]<\/a><\/sup>. Early detection through toe pressure measurement helps guide timely interventions, reducing the risk of complications.<\/p>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-12 2xl:pt-12 pb-12 2xl:pb-12 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<p class=\"has-p-big-font-size\"><strong>PAD and wound-healing reference values<sup><a href=\"#references\">[2]<\/a><\/sup><\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"w-full max-w-lg\">\n  <table style=\"border-collapse: collapse; width: 100%;\">\n    <thead>\n      <tr>\n        <th style=\"background-color: #D3D3D3; padding: 12px; text-align: center; border: 1px solid black;\" colspan=\"3\">Diagnosis<\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: left;\">ABI<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">0.9 &#8211; 1.3<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\" rowspan=\"2\">\n          <div style=\"display: flex; align-items: center; justify-content: flex-start; height: 100%; gap: 10px; margin-left: -10px;\">\n            <span style=\"font-size: 36px; font-weight: 300; line-height: 1;\">}<\/span>\n            <span style=\"text-align: left;\">PAD is less likely<\/span>\n          <\/div>\n        <\/td>\n      <\/tr>\n      <tr>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: left;\">TBI<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">\u2265 0.7<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"w-full max-w-lg\">\n  <table style=\"border-collapse: collapse; width: 100%;\">\n    <thead>\n      <tr>\n        <th style=\"background-color: #D3D3D3; padding: 12px; text-align: center; border: 1px solid black;\" colspan=\"3\">Prognosis<\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: left;\">AP (mmHg)<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">< 50<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">impaired healing<\/td>\n      <\/tr>\n      <tr>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: left;\">ABI<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">< 0.5<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">impaired healing<\/td>\n      <\/tr>\n      <tr>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: left;\">TP (mmHg)<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">\u2265 30<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">healing probability increases up to 30%<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"w-full max-w-lg\">\n  <table style=\"border-collapse: collapse; width: 100%;\">\n    <thead>\n      <tr>\n        <th style=\"background-color: #D3D3D3; padding: 12px; text-align: center; border: 1px solid black;\" colspan=\"3\">Treatment<\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: left;\"><\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center; font-weight: 700;\">Ischemia (a)<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center; font-weight: 700;\">Severe isc. (b)<\/td>\n      <\/tr>\n      <tr>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: left;\">AP (mmHg)<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">< 100<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">< 50<\/td>\n      <\/tr>\n      <tr>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: left;\">ABI<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">&#8211;<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">< 0.4<\/td>\n      <\/tr>\n      <tr>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: left;\">TP (mmHg)<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">< 60<\/td>\n        <td style=\"border: 1px solid black; padding: 12px; text-align: center;\">< 30<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n<\/div>\n<\/div>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto  pb-12 2xl:pb-12 none\">\n                        \n\n        <div class=\"section__content  max-w-4xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<p class=\"has-p-regular-font-size\">According to <sup><a href=\"#references\">[2]<\/a><\/sup>, people with diabetes should undergo toe pressure exams. If toe pressure and ABI do not correlate, toe pressure is the primary determinant of ischemia grade. If arterial calcification precludes reliable ABI or toe pressure, ischemia should be documented by Tcp02, SPP, or PVR.<\/p>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-12 2xl:pt-12 pb-12 2xl:pb-12 none\">\n                        \n\n        <div class=\"section__content  max-w-4xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-89b078ac wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><a href=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/periflux-6000-combined-system-repeatable-toe-pressure-report_1.webp\" class=\"glightbox\">\n                <div class=\"block-img relative   \" >\n                                        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/periflux-6000-combined-system-repeatable-toe-pressure-report_1.webp\" alt=\"\"\n                    width=\"875\" height=\"1236\" class=\" has-round-corners\">\n                                <\/div>\n                    <\/a>\n            <\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Accurate and repeatable toe pressures with PeriFlux 6000<\/h3>\n\n\n\n<p class=\"has-p-regular-font-size\">PeriFlux 6000 solutions are designed for clinicians to carry out pressure measurements easily. Attach the laser Doppler probe to the toe with double-sided tape, wrap a toe cuff around the toe, and start occlusion.&nbsp;<\/p>\n\n\n\n<p class=\"has-p-regular-font-size\">Our thermostatic laser Doppler probes promote measurement reliability in cases of low toe pressure caused by vasoconstriction and is a more sensitive technology than photoplethysmography (PPG).<\/p>\n<\/div>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-20  none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<h2 class=\"wp-block-heading\">Related products and applications<\/h2>\n\n\n<div class=\"gn-spacer-block pb-8\">\n    <\/div>\n\n\n<div class=\"products-grid grid grid-cols-1 md:grid-cols-3 gap-8 \"\n        >\n                    \n            <div class=\"product-card bg-white rounded-[7px] overflow-hidden\">\n                                    <a href=\"https:\/\/www.perimed-instruments.com\/us\/products\/periflux-vascular-systems\/periflux-6000\/combined\/\">\n                                                    <div class=\"aspect-w-16 aspect-h-9\">\n                        <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/periflux-6000-combined-system-2.webp\" alt=\"PeriFlux 6000 Combined System\" class=\"object-cover w-full h-full\">\n                    <\/div>\n                \n                <div class=\"p-6\">\n                    <div style=\"display: none;\">product-type <\/div>\n                    \n                    <h3 class=\"pb-2\">\n                        PeriFlux 6000 Combined System\n                    <\/h3>\n\n                                            <div class=\"text-black mb-8 text-lg product-excerpt\">\n                            A powerful, all-in-one vascular care solution designed to deliver comprehensive macro- and microvascular measurements primarily for clinical use.\r\n\n                        <\/div>\n                    \n                                            <div>\n                            <span class=\"inline-flex items-center text-black product-read-more-link\">\n                                <span class=\"mr-6 font-medium\">\n                                    Show product\n                                <\/span>\n                                <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/themes\/perimed\/public\/images\/arrow-right.d1b3f7.svg\" alt=\"Arrow right\" class=\"mt-1 w-4 h-4\">\n                                <span class=\"sr-only\">about PeriFlux 6000 Combined System<\/span>\n                            <\/span>\n                        <\/div>\n                                    <\/div>\n                                    <\/a>\n                            <\/div>\n                    \n            <div class=\"product-card bg-white rounded-[7px] overflow-hidden\">\n                                    <a href=\"https:\/\/www.perimed-instruments.com\/us\/products\/periflux-vascular-systems\/periflux-6000\/pressure\/\">\n                                                    <div class=\"aspect-w-16 aspect-h-9\">\n                        <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/periflux-6000-pressure-bg-2.webp\" alt=\"PeriFlux 6000 Pressure System\" class=\"object-cover w-full h-full\">\n                    <\/div>\n                \n                <div class=\"p-6\">\n                    <div style=\"display: none;\">product-type <\/div>\n                    \n                    <h3 class=\"pb-2\">\n                        PeriFlux 6000 Pressure System\n                    <\/h3>\n\n                                            <div class=\"text-black mb-8 text-lg product-excerpt\">\n                            For clinical\/research practice focusing on pressure exams like TBI, ABI, SPP, and segmental pressure.\n                        <\/div>\n                    \n                                            <div>\n                            <span class=\"inline-flex items-center text-black product-read-more-link\">\n                                <span class=\"mr-6 font-medium\">\n                                    Show product\n                                <\/span>\n                                <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/themes\/perimed\/public\/images\/arrow-right.d1b3f7.svg\" alt=\"Arrow right\" class=\"mt-1 w-4 h-4\">\n                                <span class=\"sr-only\">about PeriFlux 6000 Pressure System<\/span>\n                            <\/span>\n                        <\/div>\n                                    <\/div>\n                                    <\/a>\n                            <\/div>\n                    \n            <div class=\"product-card bg-white rounded-[7px] overflow-hidden\">\n                                    <a href=\"https:\/\/www.perimed-instruments.com\/us\/applications\/clinical-and-clinical-research\/peripheral-artery-disease-pad\/\">\n                                                    <div class=\"aspect-w-16 aspect-h-9\">\n                        <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/primed-peripheral-artery-disease-2.webp\" alt=\"Peripheral artery disease \u2014 PAD\" class=\"object-cover w-full h-full\">\n                    <\/div>\n                \n                <div class=\"p-6\">\n                    <div style=\"display: none;\">application_cat Clinical<\/div>\n                                            <div class=\"category-title application-category\">\n                            <span class=\"mt-2\">Clinical<\/span>\n                        <\/div>\n                    \n                    <h3 class=\"pb-2\">\n                        Peripheral artery disease \u2014 PAD\n                    <\/h3>\n\n                                            <div class=\"text-black mb-8 text-lg product-excerpt\">\n                            Early detection and accurate monitoring are critical for managing this chronic condition that affects over 113 million people globally.\n                        <\/div>\n                    \n                                            <div>\n                            <span class=\"inline-flex items-center text-black product-read-more-link\">\n                                <span class=\"mr-6 font-medium\">\n                                    Read more\n                                <\/span>\n                                <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/themes\/perimed\/public\/images\/arrow-right.d1b3f7.svg\" alt=\"Arrow right\" class=\"mt-1 w-4 h-4\">\n                                <span class=\"sr-only\">about Peripheral artery disease \u2014 PAD<\/span>\n                            <\/span>\n                        <\/div>\n                                    <\/div>\n                                    <\/a>\n                            <\/div>\n                    \n            <div class=\"product-card bg-white rounded-[7px] overflow-hidden\">\n                                    <a href=\"https:\/\/www.perimed-instruments.com\/us\/applications\/clinical-exams\/ankle-pressure-and-abi\/\">\n                                                    <div class=\"aspect-w-16 aspect-h-9\">\n                        <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/perimed-ankle-pressure-and-abi.webp\" alt=\"Ankle pressure and ABI\" class=\"object-cover w-full h-full\">\n                    <\/div>\n                \n                <div class=\"p-6\">\n                    <div style=\"display: none;\">application_cat Clinical exams<\/div>\n                                            <div class=\"category-title application-category\">\n                            <span class=\"mt-2\">Clinical exams<\/span>\n                        <\/div>\n                    \n                    <h3 class=\"pb-2\">\n                        Ankle pressure and ABI\n                    <\/h3>\n\n                                            <div class=\"text-black mb-8 text-lg product-excerpt\">\n                            The gold standard for PAD diagnosis for people without diabetes.\n                        <\/div>\n                    \n                                            <div>\n                            <span class=\"inline-flex items-center text-black product-read-more-link\">\n                                <span class=\"mr-6 font-medium\">\n                                    Read more\n                                <\/span>\n                                <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/themes\/perimed\/public\/images\/arrow-right.d1b3f7.svg\" alt=\"Arrow right\" class=\"mt-1 w-4 h-4\">\n                                <span class=\"sr-only\">about Ankle pressure and ABI<\/span>\n                            <\/span>\n                        <\/div>\n                                    <\/div>\n                                    <\/a>\n                            <\/div>\n                    \n            <div class=\"product-card bg-white rounded-[7px] overflow-hidden\">\n                                    <a href=\"https:\/\/www.perimed-instruments.com\/us\/applications\/clinical-exams\/transcutaneous-oxygen-tcpo2\/\">\n                                                    <div class=\"aspect-w-16 aspect-h-9\">\n                        <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/perimed-tcpo2-four-electrodes-1.webp\" alt=\"Transcutaneous oxygen \u2014 TcpO2\" class=\"object-cover w-full h-full\">\n                    <\/div>\n                \n                <div class=\"p-6\">\n                    <div style=\"display: none;\">application_cat Clinical exams<\/div>\n                                            <div class=\"category-title application-category\">\n                            <span class=\"mt-2\">Clinical exams<\/span>\n                        <\/div>\n                    \n                    <h3 class=\"pb-2\">\n                        Transcutaneous oxygen \u2014 TcpO2\n                    <\/h3>\n\n                                            <div class=\"text-black mb-8 text-lg product-excerpt\">\n                            Optimize patient management with PeriFlux 6000 Combined and measure TcpO2 simultaneously with ankle and toe pressure.\r\n\r\n\n                        <\/div>\n                    \n                                            <div>\n                            <span class=\"inline-flex items-center text-black product-read-more-link\">\n                                <span class=\"mr-6 font-medium\">\n                                    Read more\n                                <\/span>\n                                <img decoding=\"async\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/themes\/perimed\/public\/images\/arrow-right.d1b3f7.svg\" alt=\"Arrow right\" class=\"mt-1 w-4 h-4\">\n                                <span class=\"sr-only\">about Transcutaneous oxygen \u2014 TcpO2<\/span>\n                            <\/span>\n                        <\/div>\n                                    <\/div>\n                                    <\/a>\n                            <\/div>\n            <\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<div class=\"gn-spacer-block pb-8\">\n    <\/div>\n\n\n<section class=\"relative w-full side-margins radius-8 form-bg mx-auto pt-20 2xl:pt-20 pb-20 none\" id=\"contact-form\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading has-white-color has-text-color has-link-color has-h-2-font-size wp-elements-28fcac54cc7f04a94ab2b55e1e729ead\">Contact us<\/h2>\n\n\n\n<div class=\"wp-block-group is-content-justification-left is-layout-constrained wp-container-core-group-is-layout-d379e479 wp-block-group-is-layout-constrained\">\n<p class=\"has-white-color has-text-color has-link-color has-p-big-font-size wp-elements-0a145e7c67c2d0fbe793e37c276bb455\">Toe pressure measurement with PeriFlux 6000 provides you with robust insights to make confident, informed decisions \u2014 whether for initial diagnosis or monitoring treatment outcomes.<\/p>\n\n\n\n<p class=\"has-white-color has-text-color has-link-color has-p-big-font-size wp-elements-5768642d9b2b8d3273f6cdce883f05e9\"><br>To find out more about how to carry out toe pressure with PeriFlux 6000, its application, or our related products, we are here to help. <\/p>\n<\/div>\n\n\n<div class=\"gn-spacer-block pb-10\">\n    <\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.perimed-instruments.com\/us\/contact\/distributors\/\">Or locate your nearest distributor<\/a><\/div>\n<\/div>\n\n\n<div class=\"gn-spacer-block pb-10\">\n    <\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"forms-block \" >\n            <div class=\"hs-form-frame\" data-region=\"na1\" data-form-id=\"e8e7b983-6449-44dc-a412-93c18c060218\" data-portal-id=\"19961763\"><\/div>\n    <\/div>\n<\/div>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full references mx-auto pt-12 2xl:pt-12 pb-12 2xl:pb-12 none\" id=\"references\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<p class=\"has-p-big-font-size\"><strong>References<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li class=\"has-p-tiny-font-size\">Mills, J. L., Sr, Conte, M. S., Armstrong, D. G., Pomposelli, F. B., Schanzer, A., Sidawy, A. N., Andros, G., &amp; Society for Vascular Surgery Lower Extremity Guidelines Committee (2014). The Society for Vascular Surgery Lower Extremity Threatened Limb Classification System: risk stratification based on wound, ischemia, and foot infection (WIfI). Journal of vascular surgery, 59(1), 220\u201334.e342. <a href=\"https:\/\/doi.org\/10.1016\/j.jvs.2013.08.003\">https:\/\/doi.org\/10.1016\/j.jvs.2013.08.003<\/a><\/li>\n\n\n\n<li class=\"has-p-tiny-font-size\">International Working Group on the Diabetic Foot (IWGDF). Guidelines on the prevention and management of diabetic foot disease (2023 update). <a href=\"https:\/\/iwgdfguidelines.org\">https:\/\/iwgdfguidelines.org<\/a><\/li>\n<\/ol>\n\n\n        <\/div>\n    <\/section>\n","protected":false},"excerpt":{"rendered":"<p>Toe pressure and TBI are noninvasive macrocirculation measurements for evaluating blood perfusion in the toes, providing critical insight into vascular health. Toe pressure measurements are useful in wound healing, detecting and managing peripheral artery disease (PAD) and chronic limb-threatening ischemia (CLTI) \u2014 especially when ankle pressure may be unreliable due to noncompressible arteries.<\/p>\n","protected":false},"featured_media":1709,"parent":1033,"menu_order":0,"template":"","meta":{"_acf_changed":true,"inline_featured_image":false,"_FSMCFIC_featured_image_caption":"","_FSMCFIC_featured_image_nocaption":"","_FSMCFIC_featured_image_hide":""},"application_cat":[31],"class_list":["post-917","application","type-application","status-publish","has-post-thumbnail","hentry","application_cat-applications-clinical-exams"],"acf":{"page_layout":"fullwidth","page_header_style":"dark","page_hero_overlap_header":"no","page_custom_css":""},"_links":{"self":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/application\/917","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/application"}],"about":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/types\/application"}],"up":[{"embeddable":true,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/application\/1033"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/media\/1709"}],"wp:attachment":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/media?parent=917"}],"wp:term":[{"taxonomy":"application_cat","embeddable":true,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/application_cat?post=917"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}