{"id":4270,"date":"2026-04-29T08:15:15","date_gmt":"2026-04-29T08:15:15","guid":{"rendered":"https:\/\/www.perimed-instruments.com\/us\/?p=4270"},"modified":"2026-04-29T08:15:16","modified_gmt":"2026-04-29T08:15:16","slug":"understanding-nice-htg677-and-what-it-means-for-healthcare-in-the-uk","status":"publish","type":"post","link":"https:\/\/www.perimed-instruments.com\/us\/blog\/understanding-nice-htg677-and-what-it-means-for-healthcare-in-the-uk\/","title":{"rendered":"Understanding NICE HTG677 and what it means for healthcare in the UK"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>by <a href=\"#bio-sg\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\">Sara Gyllensporre<\/mark><\/a> (Clinical <em>Application Specialist<\/em>)<\/p>\n\n\n\n<p>For more than a decade, I\u2019ve been building relationships with clinicians and gaining valuable insights into how healthcare in the UK operates. As part of our strategy to scale in key markets, we recently partnered with HC 21 UK \u2014 one of Europe\u2019s largest medtech providers. You can read more about that in this post: <a href=\"https:\/\/www.perimed-instruments.com\/us\/blog\/strengthening-vascular-care-across-the-uk-perimed-and-hc-21-uk\/\" target=\"_blank\" rel=\"noreferrer noopener\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\">Strengthening vascular care across the UK<\/mark><\/a>.<\/p>\n\n\n\n<p>On a recent visit to the UK, I was interested to learn that some hospitals I have worked closely with are no longer using certain medical devices listed in the <mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\"><a href=\"https:\/\/www.nice.org.uk\/guidance\/htg677\/chapter\/2-The-diagnostic-tests\/#ID0E2D\" target=\"_blank\" rel=\"noreferrer noopener\">NICE HTG677 recommendation<\/a><\/mark>, which recognizes the need for specialists to perform and interpret ankle brachial index (ABI) measurements. In short, the guidance concludes that more research is needed, and that the evidence is currently insufficient to support the <strong>routine use of <em>automated<\/em> ABI measurement devices<\/strong> to detect peripheral artery disease (PAD) in people with leg ulcers.<\/p>\n\n\n\n<p>In this post, I will unpack what that means in practice. I will explore the two factors that affect ABI measurements: the physiological side of how underlying patient conditions can influence results, as well as the technical side, including how the equipment itself, regardless of method or instrument, can impact measurement quality. And lastly, I will share my thoughts on why \u2014 beyond patient outcomes \u2014 the recommendation exists and what it means for healthcare in the UK.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:20%\">\n<figure class=\"wp-block-image alignleft size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1289\" height=\"1289\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed.webp\" alt=\"\" class=\"wp-image-4259\" style=\"width:150px\" srcset=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed.webp 1289w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed-300x300.webp 300w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed-1024x1024.webp 1024w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed-150x150.webp 150w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed-768x768.webp 768w\" sizes=\"auto, (max-width: 1289px) 100vw, 1289px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n<section class=\"relative w-full mx-auto pt-20 pb-20 none\">\n                                                \n                                        <div class=\"sec-bg sec-bg-laptop absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-size:cover;background-position:center;\"><\/div>\n                                        <div class=\"sec-bg sec-bg-mobile absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-size:cover;background-position:center;\"><\/div>\n                                        <div class=\"sec-bg sec-bg-wide absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-size:cover;background-position:center;\"><\/div>\n                                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:15%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:70%\">\n<p class=\"has-text-align-center has-xl-font-size\">\u201c<em>For HC21 UK, NICE HTG677 highlights an opportunity to better support clinicians managing people with diabetes and complex wounds. By combining Perimed\u2019s PeriFlux 6000 with our local service and education, we aim to help teams strengthen vascular assessment pathways and make more informed decisions about patient care.<\/em>\u201d<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:15%\"><\/div>\n<\/div>\n\n\n<div class=\"gn-spacer-block pb-12\">\n    <\/div>\n\n\n\n<p class=\"has-text-align-right\">David Atkinson, Business Development Director \u2014 HC21 UK,<\/p>\n\n\n        <\/div>\n    <\/section>\n\n\n<div class=\"gn-spacer-block pb-12\">\n    <\/div>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"block-heading relative  \" >\n        <h3 class=\"heading    \">Leg ulcers and PAD<\/h3>\n    <\/div>\n\n\n\n<p>I think it\u2019s important to put the recommendation into context. It specifically addresses the <strong>detection of peripheral artery disease (PAD) in people with leg ulcers<\/strong>. In other words, non-trivial diagnoses of complex patients with potential comorbidities.<\/p>\n\n\n\n<p>As the recommendation explains, the rationale stems from the widespread use of compression therapy for leg ulcers. While effective, compression is not always an appropriate treatment. For individuals with underlying PAD, compression can further compromise blood flow to the limb, with potentially serious complications.<\/p>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<div class=\"gn-spacer-block pb-16\">\n    <\/div>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"block-heading relative  \" >\n        <h3 class=\"heading    \">Why measure microcirculation<\/h3>\n    <\/div>\n\n\n\n<p>One of the positives with ABI is that it is a noninvasive way to assess arterial status, but it has its limitations. While low ABI is indicative of PAD, a normal ABI does not exclude it.<\/p>\n\n\n\n<p>In some individuals, ABI may appear normal because blood can find alternative pathways around blockages. Arterial stiffness, which becomes more common with age and in people with diabetes or chronic kidney disease, can also affect the measurement. In these cases, ABI values may be falsely elevated because stiff arteries do not compress properly, causing ABI values to fall within the normal range despite underlying disease. &nbsp;&nbsp;<\/p>\n\n\n\n<p>In isolation, ABI is not always reliable. It reflects large-vessel blood flow but does not capture tissue-level perfusion where healing occurs. Measuring microcirculation helps address this gap as it can reveal ischemia and provide deeper insights into healing potential and tissue viability.<\/p>\n\n\n\n<p>Why then does the NICE recommendation focus on the technology rather than the inherent limitations of the measurement? My theory is the apparent simplicity of modern devices.<\/p>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<div class=\"gn-spacer-block pb-20\">\n    <\/div>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n<div class=\"block-heading relative  mx-auto\" >\n        <h3 class=\"heading    \">The shift to the home \u2014 at what cost? <\/h3>\n    <\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\"><div class=\"block-img relative max-w-2xl  \" >\n                                        <img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Healthcare-at-home-scaled.webp\" alt=\"\"\n                    width=\"2560\" height=\"1707\" class=\" has-round-corners\">\n                                <\/div>\n            <\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<p>The proliferation of devices for home- and community-based care is both inevitable and desirable. Driven by advances in technology and the growing need to support care at home and in remote settings, new devices are shifting diagnostics out of specialist environments and into settings closer to patients. &nbsp;<\/p>\n\n\n\n<p>While this shift helps lower the burden on healthcare systems, it introduces a subtle challenge:<\/p>\n\n\n\n<p class=\"has-text-align-center has-xl-font-size\"><strong>The assumption that ease of use equates to measurement reliability.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p>In the context of ABI, this assumption does not always hold.<\/p>\n\n\n\n<p>Automated devices make it possible for almost anyone to take a measurement. The process appears simple: wrap a cuff around the limb, press a button, and read the result. However, alongside underlying physiological factors that can affect ABI accuracy, several additional parameters come into play, including:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Correct cuff placement.<\/li>\n\n\n\n<li>Appropriate probe positioning.<\/li>\n\n\n\n<li>Interpretation of signal quality.<\/li>\n\n\n\n<li>Leaks in cuffs or tubing due to wear and tear.<\/li>\n\n\n\n<li>Limb positioning.<\/li>\n\n\n\n<li>Probe calibration.<\/li>\n<\/ul>\n\n\n\n<p>All these factors require appropriate expertise, the right clinical setting, and suitable tools. I believe that this is what the NICE recommendation is pointing to in the following statement:<\/p>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full side-margins radius-8 mx-auto pt-20 pb-20 none\">\n                    <div class=\"sec-bg-color absolute top-0 inset-0 flex justify-center overflow-hidden w-full h-full pointer-events-none z-[-2]\"  style=\"background-color:#ffffff;\">\n            <\/div>\n                        \n\n        <div class=\"section__content  max-w-7xl px-4 mx-auto sec_no_tabs\" >\n            \n<section class=\"relative w-full mx-auto pt-20 pb-20 none\">\n                                                \n                                        <div class=\"sec-bg sec-bg-laptop absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/bg-quote.webp);background-size:cover;background-position:center;\"><\/div>\n                                        <div class=\"sec-bg sec-bg-mobile absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/bg-quote.webp);background-size:cover;background-position:center;\"><\/div>\n                                        <div class=\"sec-bg sec-bg-wide absolute top-0 inset-0 flex justify-center overflow-hidden bg-no-repeat w-full h-full pointer-events-none z-[-1]\" style=\"background-image: url(https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/bg-quote.webp);background-size:cover;background-position:center;\"><\/div>\n                                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<p class=\"has-text-align-center has-xl-font-size\" id=\"h-explore-the-most-appropriate-user-specialist-and-non-specialist-in-assessing-peripheral-artery-disease-and-the-most-appropriate-healthcare-setting-for-their-use\">Explore the most appropriate user (specialist and non-specialist in assessing peripheral artery disease) and the most appropriate healthcare setting for their use.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\"><\/div>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-0 pb-0 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n<div class=\"gn-spacer-block pb-0.5\">\n    <\/div>\n\n\n<div class=\"block-heading relative  mx-auto\" >\n        <h3 class=\"heading    \">Automated versus manual ABI<\/h3>\n    <\/div>\n\n\n\n<p class=\"has-text-align-left\">Is ABI the domain of specialist vascular clinics and hospital departments, staffed by trained personnel? Can it be reliably performed in primary care by a GP? Can patients carry it out at home with an automated device? &nbsp;<\/p>\n\n\n\n<p>Manual ABI is typically performed using a handheld Doppler probe that converts arterial blood flow into an audible signal for the <strong><em>clinician to interpret<\/em><\/strong>.<\/p>\n\n\n\n<p>This is the key point of the recommendation: automated ABI reduces, and maybe even eliminates, clinician involvement from the measurement process.<\/p>\n\n\n<div class=\"gn-spacer-block pb-12\">\n    <\/div>\n\n\n<div class=\"block-heading relative  mx-auto\" >\n        <h3 class=\"heading    \">Keeping the clinician in the loop<\/h3>\n    <\/div>\n\n\n\n<p>To ensure that clinicians remain actively involved, Perimed has designed its ABI protocol to go beyond the generation of a single numerical value. Instead, it visualizes what\u2019s happening throughout the entire measurement \u2014 from patient preparation, through baseline recording, occlusion, and finally the return of flow.<\/p>\n\n\n\n<p>This continuous data capture provides insight into every phase of the measurement. It enables clinicians to assess not only whether the ABI is valid, but also whether the conditions under which it was obtained were valid, and identify physiological or technical factors that may be influencing the result.<\/p>\n\n\n\n<p>Figure (a) is a screenshot from our PeriFlux 6000 ABI protocol. It shows the baseline ankle pressure (area 1) before occlusion. This is not merely a starting point; it provides meaningful clinical context. For example, a PU below 20 may indicate underlying pathology such as microvascular disease or ischemia.<\/p>\n\n\n\n<p class=\"has-text-align-left\">The thin gray line shows the pressure in the cuff, which rises rapidly as the cuff inflates and drops uniformly as the cuff deflates following occlusion. The system automatically identifies the point of return and records the corresponding pressure. However, this marker is not blindly accepted. Clinicians are expected to verify its accuracy, ensuring that manual interpretation remains central to the measurement.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"291\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/ABI-with-PeriFlux-6000-1024x291.webp\" alt=\"\" class=\"wp-image-4271\" srcset=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/ABI-with-PeriFlux-6000-1024x291.webp 1024w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/ABI-with-PeriFlux-6000-300x85.webp 300w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/ABI-with-PeriFlux-6000-768x218.webp 768w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/ABI-with-PeriFlux-6000.webp 1387w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\"><em>Figure (a) ABI measurement with PeriFlux 6000<\/em><\/p>\n\n\n\n<p>In addition to the actual measurement, the details help clinicians to identify other issues, such as incompressible arteries and cuff wear and tear.<\/p>\n\n\n\n<p>Signs of incompressible arteries include: pulsatility after occlusion, long occlusion times, or an ABI above 1.3 mmHg. The graph in Figure (b) indicates blood flow despite a cuff pressure of 202 mmHg.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"813\" height=\"279\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/icompressible-arteries-graph.webp\" alt=\"\" class=\"wp-image-4272\" srcset=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/icompressible-arteries-graph.webp 813w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/icompressible-arteries-graph-300x103.webp 300w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/icompressible-arteries-graph-768x264.webp 768w\" sizes=\"auto, (max-width: 813px) 100vw, 813px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\"><em>Figure (b) Signs of pulsatility<\/em><\/p>\n\n\n\n<p>Our training material states that failure to achieve occlusion at 200 mmHg may indicate high blood pressure, arterial calcification, or other vascular abnormality. In such cases, we recommend repeating the measurement at a slightly higher pressure, 15-20 mmHg above the standard 200 mmHg, or proceeding with a toe pressure measurement.<\/p>\n\n\n\n<p>The advantage of PeriFlux 6000 over ABI-only solutions is that it supports a comprehensive range of assessments, providing clinicians with insight into tissue viability.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Macrovascular<\/strong> \u2014 including ABI, Exercise ABI, TBI, and PVR<\/li>\n\n\n\n<li><strong>Microvascular<\/strong> \u2014 skin perfusion pressure (SPP), TcpO2, and Exercise TcpO2 <\/li>\n<\/ul>\n\n\n<div class=\"gn-spacer-block pb-12\">\n    <\/div>\n\n\n<div class=\"block-heading relative  \" >\n        <h3 class=\"heading    \">Technical limitations, irrespective of method or instrument<\/h3>\n    <\/div>\n\n\n\n<p><\/p>\n\n\n\n<p>Over time, pressure cuffs can wear out, and issues can arise with the connections and tubing between the air outlet and the cuff. These technical factors can affect measurement accuracy regardless of whether the system is manual or automated.<\/p>\n\n\n\n<p>A non-linear cuff-pressure curve, as shown in the reference diagram, indicates an air leak, which needs to be corrected to ensure a valid ABI reading.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"766\" height=\"373\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/cuff-leakage.webp\" alt=\"\" class=\"wp-image-4274\" srcset=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/cuff-leakage.webp 766w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/cuff-leakage-300x146.webp 300w\" sizes=\"auto, (max-width: 766px) 100vw, 766px\" \/><\/figure>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-20 pb-20 none\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n<div class=\"block-heading relative  \" >\n        <h3 class=\"heading    \">What it means for healthcare in the UK<\/h3>\n    <\/div>\n\n\n\n<p>The push to decentralize vascular assessment is understandable. While NICE HTG677 challenges the assumption that ABI is straightforward, it\u2019s not a blanket rejection of automated ABI in favor of traditional manual methods. Rather, it can be read as a caution against deploying systems that oversimplify the measurement and diminish the importance of operator know-how and specialist vascular expertise. Without these, the risk is clear: convenience may come at the expense of diagnostic confidence.<\/p>\n\n\n\n<p>I hope you found this post insightful. To find out more about ABI with PeriFlux 6000 visit:<mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\"> <a href=\"https:\/\/www.perimed-instruments.com\/applications\/clinical-exams\/ankle-pressure-and-abi\/\" target=\"_blank\" rel=\"noreferrer noopener\">Ankle pressure and ABI<\/a><\/mark>.<\/p>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-20 pb-20 none\" id=\"bio-sg\">\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:600px\">\n<p><a href=\"https:\/\/www.linkedin.com\/in\/sara-gyllensporre-a67591131\/\" target=\"_blank\" rel=\"noreferrer noopener\"><mark style=\"background-color:rgba(0, 0, 0, 0);color:#0072ce\" class=\"has-inline-color\">Sara Gyllensporre<\/mark><\/a><\/p>\n\n\n\n<p>Clinical Application Specialist<\/p>\n\n\n\n<p>With over 16 years at Perimed, Sara has held multiple roles and developed a broad understanding of medtech and its application in healthcare settings. She holds a degree in pharmacology and an MSc in molecular biology and plays a vital role ensuring technology meets the needs of clinical practice, supported by strong relationships with clinicians across Europe.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:150px\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed-1024x1024.webp\" alt=\"\" class=\"wp-image-4259\" srcset=\"https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed-1024x1024.webp 1024w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed-300x300.webp 300w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed-150x150.webp 150w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed-768x768.webp 768w, https:\/\/www.perimed-instruments.com\/us\/wp-content\/uploads\/sites\/3\/Sara-Gyllensporre-Perimed.webp 1289w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<section class=\"relative w-full mx-auto pt-20 pb-20 none\">\n                    <div class=\"sec-bg-color absolute top-0 inset-0 flex justify-center overflow-hidden w-full h-full pointer-events-none z-[-2]\"  style=\"background: linear-gradient(90deg, #ffffff 0%, #92c0fd 40%, #4575b6 50%, #92c0fd 60%, #ffffff 100%);;\">\n            <\/div>\n                        \n\n        <div class=\"section__content  max-w-screen-xl px-4 mx-auto sec_no_tabs\" >\n            \n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\"><div class=\"forms-block \" >\n            <div class=\"hs-form-frame\" data-region=\"na1\" data-form-id=\"0be996c3-5f54-468f-9a1e-cf72527b6499\" data-portal-id=\"19961763\"><\/div>\n    <\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\"><\/div>\n<\/div>\n\n\n        <\/div>\n    <\/section>\n\n\n<div class=\"gn-spacer-block pb-8\">\n    <\/div>\n\n\n\n<p><strong>Disclaimer<\/strong><br>The views expressed in this blog post are those of the author and do not necessarily represent the official position of Perimed. The content is provided for informational purposes only and is not intended to constitute clinical claims or medical advice. Clinical decisions should always be based on professional judgment and applicable clinical guidelines.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>by Sara Gyllensporre (Clinical Application Specialist) For more than a decade, I\u2019ve been building relationships with clinicians and gaining valuable insights into how healthcare in the UK operates. As part of our strategy to scale in key markets, we recently partnered with HC 21 UK \u2014 one of Europe\u2019s largest medtech providers. You can read &hellip; <a href=\"https:\/\/www.perimed-instruments.com\/us\/blog\/understanding-nice-htg677-and-what-it-means-for-healthcare-in-the-uk\/\">Continued<\/a><\/p>\n","protected":false},"author":2,"featured_media":916,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"_FSMCFIC_featured_image_caption":"","_FSMCFIC_featured_image_nocaption":"","_FSMCFIC_featured_image_hide":"","footnotes":""},"categories":[38],"tags":[],"class_list":["post-4270","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog-post"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/posts\/4270","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/comments?post=4270"}],"version-history":[{"count":3,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/posts\/4270\/revisions"}],"predecessor-version":[{"id":4277,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/posts\/4270\/revisions\/4277"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/media\/916"}],"wp:attachment":[{"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/media?parent=4270"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/categories?post=4270"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.perimed-instruments.com\/us\/wp-json\/wp\/v2\/tags?post=4270"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}